AquaTrans™ AT600

+ Free Shipping

AquaTrans™ AT600
Panametrics ultrasonic flow meter for liquids

Applications: 
The AquaTrans AT600 flowmeter is a complete ultrasonic
system for the measurement of:
• Potable Water
• Wastewater
• Sewage
• Discharge water
• Treated water
• Cooling and heating water
• Irrigation water
• Other industrial fluids

Features & Benefits:
• Economical non-intrusive flow measurement
• Extremely simple setup and installation
• Suitable for a wide range of pipe sizes and materials
• Suitable for lined pipes
• Velocity, volumetric, and totalized flow outputs
• Clamp-on installations
• Permanent solid couplant for clamp-on applications

 

Liquid flow ultrasonic transmitter
The AquaTrans AT600 liquid flow ultrasonic transmitter combines state-of-the-art flow measurement capability with a low-cost transmitter package that can be installed right at the process measurement point. It’s designed specifically for water and wastewater applications in full pipes. The all digital AquaTrans AT600 has no moving parts and requires minimal maintenance. An onboard microprocessor uses patented correlation transit-time™ technology for long-term, drift-free operation. Automatic adjustment to changing fluid properties and dynamically configured operating software simplify programming. Transit-time flow measurement In this method, two transducers serve as both ultrasonic signal generators and receivers. They are in acoustic communication with each other, meaning the second transducer can receive ultrasonic signals transmitted by the first transducer and vice versa. In operation, each transducer functions as a transmitter, generating a specified number of acoustic pulses, and then as a receiver for an identical number of pulses. The time interval between transmission and reception of the ultrasonic signals is measured in both directions. When the liquid in the pipe is not flowing, the transit-time downstream equals the transit-time upstream. When the liquid is flowing, the transittime downstream is less than the transit-time upstream. The difference between the downstream and upstream transit times is proportional to the velocity of the flowing liquid, and its sign indicates the direction of flow.

Fluid Types Liquids: acoustically conductive fluids, including most clean liquids, and many liquids with small amounts of entrained solids or gas bubbles
Flow Measurement Patented Correlation Transit-TimeTM mode
Pipe Sizes 15 mm to 7600 mm (1/2 inch to 300 inch)
Pipe Materials All metals and most plastics. Consult RS Hydro for concrete, composite materials, and highly corroded or lined pipes.
Accuracy ±1% of reading in application, ≥2 in. (50 mm) pipe and >1 ft/s (0.3 m/s) velocity
±2% of reading in application, <2 in. (50 mm) pipe and >1 ft/s (0.3 m/s) velocity
±0.5% in field calibration
Installation assumes a fully developed, symmetrical flow profile (typically 10 diameters upstream and 5 diameters downstream of straight pipe run). Final installation accuracy is a function of multiple factors including fluid, temperature range, pipe centricity and others.
Calibration All meters are water calibrated and delivered with a traceable calibration certificate.
Repeatability ±0.2% of reading
Range (Bidirectional) -40 to 40 ft/s (-12.19 to 12.19 m/s)
Rangability (Overall) 400:1
Measurement Parameters Velocity, Volumetric, and Totalized Flow
Electronics
Enclosure Epoxy-coated aluminum weatherproof Type
4X/IP67
Dimensions 6.6 x 5.0 x 2.4in (168 x 128 x 61mm)
Weight: 3.5 lbs/1.5kg
Channels One channel
Display Graphic LCD (128 x 64 pixels)
Keypad Six-button keypad, for full functionality operation
Error Display Indicator Green or red light
Power Supplies Standard: 85 to 265 VAC, 50/60 Hz
Optional: 12 to 28 VDC, ± 5%
Power Consumption 10 Watts in rush
5 Watts normal operation
Operating Temperature -4°F to 131°F (-20°C to 55°C)
Storage Temperature -40°F to 158°F (-40°C to 70°C)
Outputs (Based on Configuration)
  • 4-20mA (24VDC powered, 600Ω maximum load, 1500 VDC Isolation)
  • Frequency, Pulse, Alarm (Passive output, 100VDC, 1A/1W maximum, 1500 VDC isolation)
  • HART (FSK modulation, Category Flow, Protocol Version 7.5, Device Revision 2, MFG ID 157, Device Type Code 127, Number of device variables 34)
  • Modbus/RS485 (Half-duplex, 1500 VDC Isolation)

Note: Analog outputs are Namur NE43 compliant

Certification CE, UL, CSA, (MCert approval pending)
Clamp-On Ultrasonic Flow Transducers
Temperature Ranges Standard: -40°F to 302°F (-40°C to 150°C)
Optional: -328°F to 752°F (-200°C to 400°C)See specific transducer for exact temperature range.
Mounting Fixture Anodized aluminum with stainless steel strapping
Couplant Standard: Solid couplant
Optional: Liquid couplant
Rating Standard: General purpose (IP66 or IP68)
Note: See specific transducer model for exact rating.